SPECIFICATIONS CHART
Part
Number
Brake
Port
Pressure
Port
Flow Thru
Port
Return
Port
Brake
Line Pressure
(with power)
Flow
Capacity
* 06-460-520
1/2-20 UNF
SAE No. 10
SAE No. 10 1/2-14 NPTF 1850 psi ± 50 psi 3-24 gpm
Complete unit replaced by 06-460-658
06-460-522
9/16-18 UNF SAE No. 10
SAE No. 10 SAE No. 10 1850 psi ± 50 psi 3-24 gpm
* 06-460-550
1/2-20 UNF
SAE No. 10
SAE No. 10 1/2-14 NPTF 1500 psi ± 50 psi 3-24 gpm
Complete unit replaced by 06-460-656
* 06-460-560
1/2-20 UNF
SAE No. 8
SAE No. 8 SAE No. 10 1550 psi ± 50 psi 3-24 gpm
Complete unit replaced by 06-460-656
* 06-460-570
9/16-18 UNF
SAE No. 8
SAE No. 8 SAE No. 10 1550 psi ± 50 psi 3-24 gpm
Complete unit replaced by 06-460-662
* 06-460-580
1/2-20 UNF
SAE No. 10
SAE No. 10 SAE No. 10 1500 psi ± 50 psi 3-24 gpm
Complete unit replaced by 06-460-656
* 06-460-588
1/2-20 UNF
SAE No. 10
SAE No. 10 SAE No. 10 1550 psi ± 50 psi 3-24 gpm
Complete unit replaced by 06-460-664
* 06-460-610
9/16-18 UNF
SAE No. 10
SAE No. 10 1/2-14 NPTF
950 psi ± 50 psi
3-24 gpm
Complete unit replaced by 06-460-666
* 06-460-620
1/2-20 UNF
SAE No. 10
SAE No. 10
SAE No. 10
1500 psi ± 50 psi 3-24 gpm
Complete unit replaced by 06-460-656
06-460-642
1/2-20 UNF
SAE No. 10 SAE No. 10 SAE No. 10
1550 psi ± 50 psi
3-24 gpm
* 06-460-650 1/2-20 UNF SAE No. 10
SAE No. 10
1/2-14 NPTF 1500 psi ± 50 psi
3-24 gpm
Complete unit replaced by 06-460-656
* 06-460-654
9/16-18 UNF
SAE No. 8 SAE No. 8 SAE No. 10
1500 psi ± 50 psi
3-12 gpm
Complete unit replaced by 06-460-676
* 06-460-656
1/2-20 UNF
SAE No. 10 SAE No. 10 SAE No. 10
1500 psi ± 50 psi
3-24 gpm
* 06-460-658
1/2-20 UNF
SAE No. 10
SAE No. 10 SAE No. 10
1850 psi ± 50 psi
3-24 gpm
* 06-460-660
1/2-20 UNF
SAE No. 10 SAE No. 10
SAE No. 10
1150 psi ± 50 psi
3-24 gpm
* 06-460-662
9/16-18 UNF SAE No. 10
SAE No. 10 SAE No. 10
1550 psi ± 50 psi
3-24 gpm
* 06-460-664
1/2-20 UNF
SAE No. 10
SAE No. 10
SAE No. 10
1500 psi ± 50 psi 3-12 gpm
* 06-460-666 9/16-18 UNF
SAE No. 10
SAE No. 10
SAE No. 10
950 psi ± 50 psi
3-24 gpm
06-460-668
1/2-20 UNF SAE No. 10
SAE No. 10
SAE No. 10
1000 psi ± 50 psi
3-12 gpm
* 06-460-670 SAE No. 10
SAE No. 10
SAE No. 10
1550 psi ± 50 psi
3-8 gpm
06-460-672
1/2-20 UNF
SAE No. 10
SAE No. 10
SAE No. 10
750 psi ± 50 psi 3-24 gpm
* 06-460-674
1/2-20 UNF
SAE No. 10
SAE No. 10
SAE No. 10 1500 psi ± 50 psi
3-12 gpm
06-460-676
9/16-18 UNF
SAE No. 10
SAE No. 10
SAE No. 10 1500 psi ± 50 psi
3-12 gpm
06-460-678
1/2-20 UNF
SAE No. 10 SAE No. 10
SAE No. 10
1700 psi ± 50 psi
3-24 gpm
* 06-460-680
1/2-20 UNF
SAE No. 8
SAE No. 8 SAE No. 10
1550 psi ± 50 psi
3-8 gpm
Complete unit replaced by 06-460-670
06-460-682
1/2-20 UNF
SAE No. 8 SAE No. 8 SAE No. 10
750 psi ± 50 psi
3-24 gpm
Complete unit replaced by 06-460-672
06-460-684
1/2-20 UNF
SAE No. 10 SAE No. 10 SAE No. 10
1100 psi ± 50 psi
3-12 gpm
* 06-460-686
1/2-20 UNF
SAE No. 10 SAE No. 10 1/2-14 NPTF
1500 psi ± 50 psi
3-12 gpm
Complete unit replaced by 06-460-674
06-461-520 1/2-20 UNF
SAE No. 10 SAE No. 10
1/2-14 NPTF
1850 psi ± 50 psi
3-24 gpm
Complete unit replaced by 06-461-658
06-461-550
1/2-20 UNF
SAE No. 10
SAE No. 10 1/2-14 NPTF
1500 psi ± 50 psi
3-24 gpm
Complete unit replaced by 06-461-656
06-461-610
9/16-18 UNF
SAE No. 10 SAE No. 10 1/2-14 NPTF
950 psi ± 50 psi
3-24 gpm
Complete unit replaced by 06-461-666
06-461-656
1/2-20 UNF
SAE No. 10 SAE No. 10 SAE No. 10
1500 psi ± 50 psi
3-24 gpm
06-461-658
1/2-20 UNF
SAE No. 10 SAE No. 10 SAE No. 10
1850 psi ± 50 psi
3-24 gpm
06-461-660
1/2-20 UNF
SAE No. 10 SAE No. 10 SAE No. 10
1150 psi ± 50 psi
3-24 gpm
06-461-666
9/16-18 UNF
SAE No. 10 SAE No. 10 SAE No. 10
950 psi ± 50 psi
3-24 gpm
06-461-674
1/2-20 UNF
SAE No. 10 SAE No. 10 SAE No. 10
1500 psi ± 50 psi
3-12 gpm
• For use with drum brakes (has residual check valve)